TransVision™ 4 RS-232 Control
The RS-232 interface for the TransVision
4 System can be operated from any
terminal, such as a Windows based PC running HyperTerminal.
Communication Port Set-Up Connector pin-out
Baud Rate: 9600 3 TX (Transmit Data)
Parity: none 2 RX (Receive Data)
Stop bits: 1 5 GND (Signal Ground)
Num. of bits: 8 bits
Flow control: none
Each command is enclosed in the
[ ] character envelope.
Note: Sequential commands must be separated with proper delays.
Any command followed by POWER ON must be delayed 10 seconds.
Any command followed by
INPUT SELECT must be delayed 1 second.
The following table lists the commands available:
[LH] Lamp Hours Transmits Lamp Hours in ASCII characters.
POWER CONTROL
[PON] Power on
[POFF] Power off
ASPECT RATIO SELECT
[S1] Standard (4:3)
[S2] Anamorphic or HD
[S3] Letterbox
[S4] Custom
RELAY CONTROL
[Y1ON] RY1 on
[Y1OFF] RY1 off
[Y2ON] RY2 on
[Y2OFF] RY2 off
INPUT SELECT
[I1] Video 1
[I2] Video 2
[I3] S-Video 1
[I4] S-Video 2
[I5] YCrCb 1
[I6] YCrCb 2
[I7] RGB 1
[I8] RGB 2
[I9] DVI 1
[I0] DVI 2